APC Network Management Card 2, 10/100 Base-T


 

 

 

APC Network Management Card 2, 10/100 Base-T
 
 


 
 
 

 

 

Výrobce

APC

 
Kód37277
Part No.AP9630
Dostupnost
k dispozici do 48 hodin
 
Vaše cena  Cenu zjistíte po přihlášení 
Záruka24 Měsíce
Objednat



 
 
 



 
 
 

  •  
 

Podrobnosti o produktu


 

Popis produktu:

novinky vůči AP9617:
-Command Line Interface replaces the Console Menu Structure for Telnet access to the card.  This enables users to more easily run scripts via Telnet or locally via the configuration port.
-Improved processing speeds which allows users to quickly download logs and more efficiently upload security certificates.
-Improved security with up to 2048-bit encryption.

-Configuration port for local configuration of the UPS Network Management Card.

Note: You cannot install this Network Management Card in a Symmetra PX 250 or Symmetra PX 550 UPS.

Running a Multiple-UPS Configuration (Smart-UPS and Symmetra)
A multiple-UPS configuration is also know as a "redundant UPS" configuration where one of several UPSs a) only partially shares the load or b) operates as a stand-by to back up a faulty unit.
Specifically, PowerChute Network Shutdown can manage up to three Smart-UPS or Symmetra units (of the same model type) providing redundant backup power to a single server. In this configuration, each UPS in the system has its own Network Management Card (AP9630, or AP9631) with PowerChute Network Shutdown recognizing the entire configuration as a single UPS.
Caution: In a multiple-UPS configuration, each UPS must have enough capacity to carry all the electrical load of the computer system. So, for example, if you had two UPSs in a multiple configuration, and one stops supplying power, the other UPS must have enough capacity to continue supplying power to protect the computer system.
For a multiple-UPS configuration, you must have PowerChute Network Shutdown 2.2 or greater. See also Requirements.
You can't upgrade to a multiple-UPS configuration from a previous version of PowerChute Network Shutdown: you must uninstall, install the new version, and reconfigure your options.
With a multiple configuration, PowerChute Network Shutdown always recognizes and logs the events in the groups listed below (see the text on individual events in the List of Events section in Help.html):
• Network communication lost events
• UPS communication lost events
• UPS off
• UPS on battery events
• Environmental Monitoring Card events
• Runtime Exceeded

For the Environmental Monitoring Card and Runtime Exceeded events, any actions you configured for the event will be instigated (see the Configuring Events section in Help.html).
Notes: With multiple-UPS configurations:
• PCNS always considers either a) a low battery condition or b) a UPS off condition as a critical event.
• Two critical events in succession always cause a shutdown. In addition, with any of these configurations, a critical event will cause an immediate shutdown; no delay time will be counted.


 

Obchodníci


 

Produkt manažer:

Jiří Adamčík, 572 433 862, 777 595 463, adamcik@premocz.eu




 
 
 



 
 
 

 

Poslat info


 

 
 
 


 



 
 


Košík
0 položek
0

 

 

 



 
 
 


 


 
Přihlášení
 


 

 

 

Technické řešení © 2018 CyberSoft s.r.o.

Podle zákona o evidenci tržeb je prodávající povinen vystavit kupujícímu účtenku. Zároveň je povinen zaevidovat přijatou tržbu u správce daně online, v případě technického výpadku pak nejpozději do 48 hodin.

 
 
 

K provozování našeho webu horn.cz využíváme takzvané cookies. Cookies jsou soubory sloužící k přizpůsobení obsahu webu, k měření jeho funkčnosti a obecně k zajištění vaší maximální spokojenosti. Používáním tohoto webu souhlasíte se způsobem, jakým s cookies nakládáme.